Description

kit contains

1 rf complaint voltage regulator with adjustment

1 multi meter for battery measurements

24v wiring harness

1 spare 12v battery charger  smart charger

1 testing tag

how to use

  1. place the colored and labelled link wire between the positive (red) of one battery and the negative (black) of another
  2. use the multi meter to measure the voltage on the two remaining contacts that have no cable attached. You should read a voltage of around 24v
  3. connect the bootlace connectors cables  (look like the plastic bit of a shoes lace but metal and blue plastic) into the clips which previously were connected to the 12v battery pack red to red and black to black
  4. make sure the knob on the regulator is set to its lowest setting (see dial indicator) on the case
  5. place this regulator  module in the waterproof housing
  6. connect the ring bolt terminals on the regulator to these remaining contacts you have just measured on the batteries red to red and black to blacktesting
  7. adjust the knob until the Amps A on the PIT reader reads 0.75A
  8. take the tag to do a range test looking for circa 1m +/-8% from the top of the white pipe taken from the center of the antenna.
  9. If the read range is too low increase the current slightly by further adjusting the knob but do not let it exceed 1.1A!!
  10. do this in small steps and repeat until you get a good read range at a safe current consumption (A)
  11. the lower the current the better as you will reach a point where the current will increase but will not drastically change the read range
  12. NOTE on checking the voltage of the battery pack, it is now wired into a 24v configuration. A low/ dead battery now being 22v as opposed to 11v